Overview
The SERIES X relay is a non-latch, 2 PDT (Polarized Double Throw) relay designed for low-level applications up to 5 amps.
Key Features
Hermetically sealed, corrosion-resistant metal can; qualified to MIL-PRF-6106; and available in various mounting styles and terminal types.
Electrical Characteristics
Contact rating per pole and load type: 5 amps at 28 Vdc, 115/200 Vac, and 400 Hz; with low-level endurance test and inductive load life.
Coil Characteristics
Nominal operating voltage: 28 Vdc; maximum operating voltage: 48 Vdc; and coil resistance: 500 ohms at +25°C.
General Characteristics
Temperature range: -70°C to +125°C; minimum operating cycles: 100,000 at rated load and 400,000 at 25% rated load; and dielectric strength: 1000 Vrms at sea level.