SERIES V110 DC Voltage Sensor Overview
The datasheet provides detailed information on the SERIES V110 DC voltage sensor, which is designed with either 2 PDT (Pole Double Throw) or 4 PDT contact configurations and capable of handling 10 amp loads. The sensor is hermetically sealed, with a maximum weight of 10 oz. It operates efficiently within a substantial DC sensing range of 0 to 50 Vdc and a wide temperature range from -55°C to +125°C. Moreover, custom configurations for specific requirements are readily available.
The general specifications for the V110 series include an input voltage range of 19.5 to 30 Vdc, pick-up and drop-out times of up to 50 ms, and a sensing accuracy between ±2% to ±10%. With regard to the operating conditions, the device can function with a maximum current of 75 milliamperes and is designed to withstand voltage transients as delineated by MIL-STD-704A, CAT.B. The sensor showcases a high endurance with a minimum of 100,000 operating cycles at rated resistive load and is engineered to resist challenging environmental conditions, such as vibrations from 5 to 80 Hz at 20 g and from 80 to 2000 Hz at 50 g, shock for 11 ± 1 ms with a 1/2 sine across 3 axes, and acceleration of 20 g in any axis.
For surface finishes, a tin plate per MIL-T-10727 is used. In order to select a suitable sensor, customers are prompted to refer to a detailed ordering system. It includes options for a basic series designation, output configurations, trip points, temperature and accuracy, as well as mounting styles and terminals.
Contact Information & Additional Notes
The datasheet lists regional contact details for Esterline Power Systems in the Americas, Europe, and Asia, featuring LEACH@ power and control solutions. Users are advised to make contact with Esterline Power Systems for component selection and detailed information.
Technical Features Highlighted
The datasheet mentions specific features such as dielectric strength with variations depending on the contact rating, hysteresis to prevent cycling due to minor voltage changes at the trip point, and a reminder to contact the factory if the standard voltage sensor specifications do not meet user requirements.
It is important to note that datasheet content serves primarily for initial product selection and comparison. The datasheet underlines the operational mode where the output relay activates when voltage exceeds the trip point and turns off as the voltage falls below that point. This ensures reliability and consistency in performance across varied application scenarios.