Aries offers a wide range of DIP jumper configurations and wiring possibilities with reliable, electronically tested solder connections and protective covers that provide strain relief for cables.

The header body and cover are made of black UL 94V-0 4/6 Nylon, and the header pins are Brass 1/2 hard with standard Pin plating of 10u [.25um] min. Gold per MIL-G-45204 over 50u” [1.27um] min. Nickel per QQ-N-290.

Specifications:

The cable insulation is UL Style 2697 Polyvinyl Chloride (PVC), and the laminate is clear PVC, self-extinguishing.

The cable has a current rating of 1 Amp @ 10°C [50°F] above ambient, a voltage rating of 300 Volts, and a temperature rating of 176°F [80°C].

Ordering Information:

The cable length is specified in inches, and the optional suffix is (see table).

The propagation delay is 1.5 ns/ft [4.9 ns/meter] nominal, and the insulation resistance is 10^10 Ohms (10 ft. [3 meters] min.).