MIL-STD-1553 Data Bus Transformers
The Pascall P1200 Series of Data Bus Transformers is designed to meet the requirements of MIL-STD-1553A/B (Def. Stan. 00-18 (Part 2)) and can be used in either bus coupling or isolation configurations.
Key Features
Compatible with currently available transceivers and integrated terminals, meeting all electrical requirements of Manchester II serial bi-phase data transmission, including MACAIR specifications.
Operating Conditions and Electrical Characteristics
Frequency range: 75 kHz to 1 MHz. Operating temperature: -55°C to +125°C. Storage temperature: -55°C to +150°C.
Electrical characteristics include open circuit primary impedance, droop, common mode rejection ratio, overshoot and ringing, inter-winding resistance, turns ratio tolerance, peak working voltage, and isolation resistor tolerance and rating.