This datasheet describes a series of 10/100Base-TX transformer modules designed for Auto MDI/MDIX applications.
The modules are RoHS compliant and have a peak reflow temperature rating of 245°C. They are approved for use with the Broadcom BCM5226 and Level One LXT9784, and meet the IEEE 802.3 specification.
Electrical Specifications
The modules operate at a temperature range of -40°C to 70°C and have a maximum insertion loss of 1.0 dB.
They also have a minimum differential to common mode rejection of 40 dB and a minimum return loss of 18 dB.
Part Numbers and Packaging
The part numbers include HII4INL, HI164NL, and HXI234NL, with options for tape and reel packaging.
The modules have a moisture sensitivity level of 2 and are available in a variety of packaging options.