This service information bulletin announces additional information regarding error codes 1403-1407 encountered when attempting an adjustment/calibration of the EyeSight system after body repair procedures have been performed.

Summary of the Bulletin:

The bulletin provides guidance on how to diagnose and correct EyeSight system errors after body repair procedures.

Key Steps:

• Perform a zero adjustment of the digital angle gauge at the lower end flange side of the rocker panel and measure the rocker angle on both sides.

• Inspect the tires and suspension height and retry aiming if necessary.

• Remove the EyeSight cover and camera and measure the EyeSight plate angle.

• Check items 1-12 listed on page 3 and reattempt aiming if necessary.

• If the aiming is unsuccessful, diagnose and repair the error code and retry aiming.

Important Notes:

• Make sure to measure near the center of the side rocker panel and NOT on the jack positions.

• The specified vehicle tolerance tilt range must be within the specified range.